Next: Block III: Frequency Selection
Up: Input Files for OASM
Previous: Block I: Title of
Similarly to the other modules, the output is controlled by a number
of one-letter options:
- B
- Bartlett Beamformer [13].
- M
- Maximum Likelihood Method (MLM) Beamformer [13].
- Q
- Multible Constraint Method (MCM) Beamformer
[14].
- T
- Tolerant beamformer. One of ABB's inventions, not yet
published. The estimated spatial coherence and the tolerance must be
specified in Block VII.
- W
- Plane wave replicas. Used in combination with any of the beamformers.
- K
- Blurring of covariance matrix corresponding to the coherence
length specified in Block VIII.
- D
- Produces a contour plot of the ambiguity function vs depth
and range (for matched field processing) for each of the selected
beamformers. The plot axes are determined
automatically to fit the replica space. If option W (plane wave
beamforming) is also specified, the ambiguity function will be
contoured vs azimuth (bearing) and vertical angle (grazing, positive
downward).
- R
- Produces a contour plot of the ambiguity function vs x-range
and y-range (for matched field processing) for each of the selected
beamformers. The plot axes are determined
automatically to fit the replica space. This option has no effect for
option W (plane wave
beamforming)
- X
- Produces an expanded printout of beamformer results.
Next: Block III: Frequency Selection
Up: Input Files for OASM
Previous: Block I: Title of
henrik schmidt
1999-08-25