Next: Block VII: Wavenumber Sampling
Up: Input Files for OASS
Previous: Block V: Scattering parameters
OASS will compute the reverberant field on arbitrary
three dimensional arrays. The first line of this block specifies the
number of sensors. Then follows the position, type and gain for each
sensor in the array. The sensor positions are specified in
cartesian coordinates in meters. The types currently
implemented are as follows
- 1.
- Hydrophone. Normal stress
(negative of pressure in
water) in Pa for source level 1 Pa (or Pa for source level 1 Pa).
- 2.
- Geophone. Particle velocity
in x-direction
(horizontal). Unit is
m/s for source level 1 Pa (or m/s for source level 1 Pa).
- 3.
- Geophone. Particle velocity
in y-direction
(horizontal). Unit is
m/s for source level 1 Pa (or m/s for source level 1 Pa).
- 4.
- Geophone. Particle velocity
in z-direction
(vertical, positive downwards). Unit is
m/s for source level 1 Pa (or m/s for source level 1 Pa).
The gain is a calibration factor in dB which is applied to
ambient noise and signal on all sensors. Note: OASS v 1.7 does
not currently allow for mixed arrays.
Next: Block VII: Wavenumber Sampling
Up: Input Files for OASS
Previous: Block V: Scattering parameters
henrik schmidt
1999-08-25