next up previous contents
Next: Block VII: Wavenumber integration Up: Block II: RDOASP options Previous: Block V: Sources

Block VI: Receivers

The default specification of the virtual source/receiver arrays used for coupling the field between the sectors is the same as for RDOAST, i.e. through the parameters RD1, RD2 and NRD in Block VI, with

RD1
Depth of uppermost virtual source/receiver in meters
RD2
Depth of lowermost virtual source/receiver in meters
NRD
Number of virtual source/receivers

The NRD receivers are placed equidistantly in the vertical.

The physical receiver depths are specified similarly on a separate line. It should be noted that for each depth, the code will compute the field at the closest virtual receiver depth.

D1
Depth of uppermost physical receiver in meters
D2
Depth of lowermost physical receiver in meters
ND
Number of physical receiver depths



henrik schmidt