next up previous contents
Next: Tilted Receiver Arrays Up: Receivers Previous: Receivers

Non-equidistant Receiver Depths

In OASP3D the receiver depths can optionally be specified individually. The parameter NR is used as a flag for this option. Thus, if NR < 0the number of receivers is interpreted as -NR, with the individual depths following immidiately following Block VI. As an example, to run the SAFARI-FIPP case 2 problem with automatic sampling, and a point force within the sea bed at angle with the sea bed, and horizontal angle relative to the x-axis, and with receivers at depths 100, 105 and 120 m, change the data file as follows:

SAFARI-FIPP case 2. Auto sampling. Force 30/45 deg
V H f                         # Bessel integration.
5 0
4
  0    0     0 0   0   0   0
  0 1500     0 0   0   1   0
100 1600   400 0.2 0.5 1.8 0
120 1800   600 0.1 0.2 2.0 0
2 1.0 30.0 45.0                # ITYP, FMAG, HANG, VANG  
101                            # SD = 101 m
100 100 -3                     # 3 receivers
100.0 105.0 120.0              # Receiver depths in meters
300 1E8                      
-1 0 0                         # NW   =   -1
2048 0.0 12.5 0.006 0.5 0.5 5

The PP Post-processor is compatible and will depth-stack the traces at the correct depths.



henrik schmidt